PT500-707
    Model: PT500-707
    Precision stable pressure core body;
    Process connection structure design of refrigerant medium (air conditioning, cold storage, etc.);
    Stainless steel process connection, 7 / 16-20nuf standard thread;
    Fatigue resistance, impact resistance and good repeatability;
    It can replace the same type of foreign products;
    Common keywords:
    Refrigerant pressure transmitter refrigerant pressure sensor
    Air conditioning pressure transmitter air conditioning pressure sensor
    Product description of strain type pressure transmitter:

    Model: PT500-707
    Precision stable pressure core body;
    Process connection structure design of refrigerant medium (air conditioning, cold storage, etc.);
    Stainless steel process connection, 7 / 16-20nuf standard thread;
    Fatigue resistance, impact resistance and good repeatability;
    It can replace the same type of foreign products;

    Common keywords:
    Refrigerant pressure transmitter refrigerant pressure sensor
    Air conditioning pressure transmitter air conditioning pressure sensor



    Chip:
    It adopts precision stable pressure sensitive chip and selective placement technology;
    Small range chip: oil filled silicon chip;
    Large range chip: piezoresistive thick film chip;
    Zero point, fullness, temperature compensation and linear compensation;
    High impedance, high precision and high stability;
    More than 1 million times of service life;

    Signal processing and output:
    24 bit ADC sampling and processing chip;
    DSP digital signal conditioning algorithm;
    Multipoint linear temperature calibration;
    Voltage and current overload protection;
    Standard industrial signal output: 4-20mA (two-wire system), 0-20mA (three wire system), 0-5vdc, 0-10vdc, 0.5-4.5vdc (three wire system);

    Digital communication signal output: rs485-rtu, ultra-low power rs485-rtu
    Advanced 32 bit microprocessor and 24 bit ADC are adopted
    The transmission protocol is MODBUS-RTU
    Support baud rate: 1200 ~ 57600bps, check bits: none, odd, even
    Support the user's secondary calibration, reset, anti reset, restore factory operations
    Support 11 kinds of units switching, support floating point, integer, percentage, formatted output
    The acquisition interval of 0 ~ 43200 seconds (12 hours) can be set, which can not only meet the needs of high-speed acquisition, but also trigger acquisition once to minimize power consumption

    Digital communication signal output: CAN2.0B
    Measurement rate: 10... 1000Hz can be set, the default is 50 Hz

    CANopen output built-in complete CANopen protocol stack, in line with ds301, ds404 specifications, support LSS services, support bootloader online upgrade;
    Support baud rate (kbps) 20 / 50 / 100 / 125 / 250 (default) / 500 / 800 / 1000; support features of NMT / heartbeat / SDO / PDO / LSS / bootloader; CANopen protocol stack can be customized according to user requirements;

    J1939 output has built-in J1939 protocol stack. PGN, SPN and name can be configured freely, and bootloader online upgrade is supported;
    Support baud rate (kbps) 20 / 50 / 100 / 125 / 250 (default) / 500 / 800 / 1000; support free configuration of features such as PGN, SPN and name
    The J1939 protocol stack can be customized according to the user's requirements;

    Structure:
    Deep argon arc welding, connecting elastic material and process joint, high strength, impact resistance and fatigue resistance;
    Process connection structure design of refrigerant medium (air conditioning, cold storage, etc.);
    Stainless steel process connection, 7 / 16-20nuf standard thread;
    Fatigue resistance, impact resistance and good repeatability;
    Process connection material: 304 or 316;

    Application:
    Pressure measurement and control of air conditioning, cold storage and other refrigerant media;
    Pressure measurement of equipment in building / industry / power / Petroleum / automation fields;

    Application fields:
    • Central air conditioning unit

    • Air compressor unit

    • Gas supply system

    • Gas supply pipeline

    Specification parameter
    Measuring medium: liquid, gas, steam, etc
    Measuring medium: refrigerant, liquid, gas, etc
    Pressure form: gauge pressure, absolute pressure
    Range:
    0~0.6、1、2、5、10、15、20、25、30、40、50、60(MPa);
    0~10、20、30、50、100、150、200、300、400、500、600(KPa);
    ±10KPa~±100KPa;
    Comprehensive accuracy: ± 0.25% FS; ± 0.5% FS; ± 1% FS
    Nonlinearity: ≤ 0.25% FS
    Repeatability: ≤ 0.15% FS
    Pressure output signal:
    Current type: 4-20mA two-wire system; 4-20mA / 0-20mA three-wire system
    Voltage type: 0 ~ 5VDC, 0 ~ 10VDC, 0.5 ~ 4.5vdc three wire system
    Supply voltage:
    5VDC (0.5 ~ 4.5vdc output type)
    24 VDC (9 ~ 30 VDC) universal type
    Service life: ≥ 1 million times
    Insulation impedance: ≥ 1000 m Ω / 100VDC
    Load impedance: current output: ≤ 800 Ω; voltage output: ≥ 50K Ω
    Medium temperature: - 20 ~ 80 ℃
    Ambient temperature: - 20 ~ 70 ℃
    Compensation temperature: 0 ~ 70 ℃
    Response time: ≤ 5ms
    Overload pressure: 150% FS
    Failure pressure: 3 times of measuring range (less than 40MPa); 2 times of measuring range (measuring range greater than 41mpa)
    Electrical connection: Waterproof tight wire nut directly leads out;
    Protection grade: IP67 / IP68
    Connecting cable: four core shielded cable, standard length: 3M

    Connection material: 304 / 316L






    Ordering considerations

    Precautions for ordering PT500-707 products
    1. Product range selection:
    In order to achieve the best effect of product accuracy, life, stability and other functions, the range selection of the product is calculated by referring to the 

    following formula:
    Range = x (1.2-1.5) times of the maximum system pressure;
    The actual measuring pressure range of the product should be 15% - 80% of the range;

    2. Product power supply and output:
    The selection of power supply range is determined according to the output specifications of the product:
    Conventional 4-20mA / 0-20mA, 0-5V / 10V output, DC 12-30vdc power supply;
    General rs485-rtu output, DC 12-30vdc power supply;
    0.5-4.5vdc output, DC 5VDC;
    Low power output power supply range: 3.6vdc (3-5vdc)

    3. The user should understand the measurement medium characteristics of the product:
    Medium specification, medium temperature, medium purity (whether containing impurities or particles, etc.);

    4. Users should understand the installation environment and installation method of the product:
    Whether the flameproof protection level can meet the requirements of field conditions;
    Indoor or outdoor installation;
    Ambient temperature;
    Required sealing level;
    Vibration range of equipment;
    Installation method: thread, flange, special structure;
    Whether the installation space meets the overall dimension of the product;
    Precautions for use

    Different product signal output specifications correspond to different power supply range requirements;
    It is strictly prohibited to use hard objects (such as screwdriver, finger, iron nail, etc.) to make the pressure diaphragm output under pressure measurement;
    The power and signal wires shall be correctly wired according to the specifications of the ordered products;
    During product installation, the stressed part is "process connection hexagon wrench position", and the wrench specification corresponds to hexagon;
    It is strictly prohibited that the medium temperature, pressure range and excitation voltage of the tested system exceed the rated use range of the transmitter;
    Pay attention to protect the outgoing cable of the transmitter. When the span is too large on site, it is recommended to use metal pipe for protection or overhead;
    The pressure transmitter is a precision measuring instrument. Do not impose impact or smash to avoid damaging the core
    The product is installed in a ventilated, dry and non corrosive environment, and installed in the open with protective devices to avoid direct sunlight;
    It is strictly prohibited to enter / leak / soak water in the product instrument, and protective devices shall be installed in the open to avoid direct sunlight;

    Common problem
    Proposal
    Name
    Tel
    QQ
    WeChat
    Mailbox
    Address
    Content
    Foshan puliang Electronic Co., Ltd

    Tel:0757-26619568 Fax: 0757-26619508

    24-hour online technical support:13790092618

    Cloud platform:www.puliangiot.com

    Address:501, block 8, phase 5, Rongli tianfulai industrial city, Ronggui town, Shunde District, Foshan City

    Copyright©Foshan puliang Electronic Co., Ltd